Refrigeration Control Engineer - Level 3
Company: Columbia University
Location: New York
Posted on: November 8, 2024
Job Description:
- Job Type: Support Staff - Union
- Bargaining Unit: TWU - B&G
- Regular/Temporary: Regular
- End Date if Temporary:
- Hours Per Week: 40
- Standard Work Schedule: Monday- Friday, 7:00AM- 3:30PM
- Building: Manhattanville Campus
- Salary Range: $54.19 - $54.19
The salary of the finalist selected for this role will be set based
on a variety of factors, including but not limited to departmental
budgets, qualifications, experience, education, licenses,
specialty, and training. The above hiring range represents the
University's good faith and reasonable estimate of the range of
possible compensation at the time of posting.
Position Summary
A Refrigeration Control Engineer (RCE) is a position in the
facilities department providing high quality and effective work
that will lead, perform and/or assist in any routine or emergency
operations and functions of the District Energy System (DES) and
the Distributed Systems throughout the Columbia
University-Manhattanville Campus (CUMVC). Perform daily functions
as required for the most effective and efficient operation of
campus system, chillers, water treatment, air conditioning,
ventilation systems and associated auxiliary equipment and
controls, including curtailment activities as required by
Consolidated Edison (ConEd) or other regulating authorities.
Independently or under limited/minimal supervision and/or
direction; operate, inspect/round, maintain,
troubleshoot/diagnosis, and repair equipment, systems, and
machinery in good workmanlike manner, while maintaining a high
level of safety, reliability, efficiency, and cost effectiveness.
May work in conjunction with the Plant Operations Engineer (POE) or
the DES Engineer to insure proper rounds and log entries are
recorded, or operate in the Engineer's absence.
Responsibilities
- The RCE will perform daily refrigeration & controls engineering
assignments required by maintenance and/or job orders, by sketch,
blueprint illustration, and supervisor's oral directions in
operations.
- Maintain, repair and operate system controls and refrigeration
equipment, auxiliary systems and computer monitoring systems while
working independently or under limited supervision and direction
and in accordance with sound engineering practices.
- Conduct start up, shutdown, and stabilization as necessary to
maintain units in efficient service.
- Conduct regular inspections of MERs, chiller system, and
auxiliary equipment to ensure proper operation and
maintenance.
- Sampling of all campus water loops and maintain/adjust proper
chemical levels within design limits.
- Monitor, document, and control refrigerant on campus to comply
with USEPA, NYSDEC and NYCDEP standards and permits.
- Understand fundamentals of electrical motors, controls,
switches, fusing and wiring, including basic electrical controls
troubleshooting.
- Operate electric chillers, steam turbine chillers, condensate
pumps, air compressors, booster pumps, auto steam reducing
stations, plate and frame HX, shell and tube HX, DDC and pneumatic
control systems.
- Operate, service, and maintain associated equipment such as air
compressors, scroll compressors, softeners, polishers, air
conditioning and ventilating equipment; direct the servicing of
chillers, water pumps, vacuum and oil pumps, valves and other
associated equipment.
- Enter and review log book entries for chillers and operating
records, indicator, meter, gauge, use and other instrument readings
as required for log entries and for monitoring system
performances.
- Make daily operating decisions and takes appropriate action in
emergencies.
- Perform preventive and proactive maintenance on equipment and
systems, such as seasonal maintenance of chillers and towers, tube
cleaning and flushing on chillers, various types of heat exchangers
and all auxiliary equipment.
- Inspect, maintain, and service all types of refrigerant systems
and equipment including MRI chillers and associated secondary
systems (i.e. Chilled beams).
- Follow and perform chiller system operations and equipment
rounds in accordance with good engineering practices.
- Remain current on all changes in operating procedures, new
equipment, and related systems.
- Perform (assist with) troubleshooting and initial root cause
analysis on equipment failures and operational upsets and recommend
proper corrective actions.
- Assist and/or direct mechanics and technicians as required to
troubleshoot issues, and properly repair, maintain, test, or
inspect equipment and/or systems.
- Diagnose operational problems, control, and equipment
malfunctions, and initiate corrective action. Notify supervisor for
major repairs, or events.
- Conduct job-site inspections to determine compliance to
standards and codes.
- Respond to various calls throughout the CUMVC relating to HVAC,
refrigeration, and other related maintenance issues.
- Work alongside and assist other personnel, including licensed
personnel, in completing assigned maintenance and service of
controls and refrigeration systems and their associated
equipment.
- Provide guidance, direction, and on the job training to all
junior personnel in the proper procedures of operations, repair,
and maintenance.
- Assist the POE and the DES Engineer in the operation and
performance of the chilled water system of the District Energy
System and all Auxiliary Equipment. Assume watch as
needed.
- Monitor and respond to the building management system (BMS) and
supervisory control and data acquisition (SCADA) as needed or
directed.
- Fully utilize the BMS to operate and maintain systems
efficiently and effectively; may include adjusting PID control
loops, setpoints, and schedules.
- Use, install, and inspect fire stopping materials.
- Requisitioning of parts and supplies as necessary to maintain
equipment and systems.
- Process hot work permits and perform necessary fire watch
procedures and inspections.
- Process paperwork including but not limited to work orders,
inventory, and preventive maintenance forms.
- Perform work tasks, report deficiencies, and maintain and
complete daily records of labor and materials used during work
tasks via the CMMS (Computerized Maintenance Management
System).
- Maintain completeness, timeliness, and accuracy of the work and
work orders.
- Continually and urgently communicate with supervisor regarding
any apparent operational deficiencies or system
malfunctions.
- Work with other disciplines and management to proactively solve
complex, multi-discipline problems.
- Must perform any duties assigned in an emergency as determined
by management.
- Attend and participate in all departmental trainings and
meetings.
- Attend and complete relevant on-the-job training as
required.
- Ability to perform all tasks and duties related to the
Refrigeration Control Engineer Level 2 position if
required.
- Perform other related duties incidental to the work herein.
Minimum Qualifications
- HS diploma or GED
- Must demonstrate minimum professional proficiency in the
English Language; as defined by the U.S. Department of
State.
- NYC Refrigeration Engineer's License in reference to Columbia
University, District Energy System address.
- Three (3) years internal experience as a Refrigeration Control
Engineer - Level 2; or external equivalent of seven (7) years of
experience as a HVAC&R mechanic.
- Six (6) years of experience operating a chiller plant under
active license and certifications.
- Knowledge of various types of chillers, HVAC&R controls,
and operating knowledge.
- Two (2) years of experience with automated systems controls;
open loop and closed loop controls systems. (Siemens, Johnson
Controls, Honeywell, etc.)
- Must be a quick learner and exhibit self-motivational
skills.
- Adequate ability to discern colors for monitoring alarm
conditions.
- Strong team mentality (ability to work with others).
- Well-refined interpersonal skills with the ability to
communicate with all levels of staff, customers, clients, students,
vendors, and management.
- How to read and interpret SDS information.
- Understanding of general vivarium, and laboratory rules and
restrictions.
- How to identify a fire rated barrier and properly install
fire-stopping materials.
- Must be able to work all shifts as assigned.
- Advanced knowledge of how to operate, navigate, manipulate, and
interpret building management systems (BMS).
- Basic knowledge of microprocessor controls; e.g.
OPTIVEIW.
- Advanced knowledge and understanding of Siemens Operating
Systems (e.g. Desigo) and other controls systems that may be
installed as the campus construction continues.
- Demonstrates an understanding of the fundamentals of electrical
motors, controls, switches, fusing and wiring, and circuit breaker
coordination.
- How to properly utilize lock out-tag out procedures for all
energy sources (electrical, thermal, hydraulic, hydronic)
- How to properly and safely operate all hand tools, power tools,
and equipment utilized by facilities maintenance and repair
including specialty HVAC, automated controls, and chiller
maintenance equipment.
- Hold and maintain Certificate of Fitness for Fire Guard
(F-60)
- Hold and maintain Certificate of Fitness for Using Powder
Activated Tools (E-21)
- Hold and maintain Certificate of Fitness for Torch Operations
(G-60)
- Hold and maintain Certificate of Fitness To Operate and
Maintain Air Compressors (A-35)
- Hold and maintain Certificate of Fitness for City Wide
Sprinkler Systems (S-12)
- Hold and maintain Certificate of Fitness for City Wide
Standpipe Systems (S-13)
- Hold and maintain Certificate of Fitness for Standpipe for
Multi-Zone Systems (S-14)
- Hold and maintain Certificate of Fitness for Supervision of
Bulk Oil Plants (P-12)
- Hold and maintain Certificate of Fitness for Supervise Fuel-Oil
Piping and Storage in Buildings (P-98)
- Hold and maintain Certificate of Fitness for Handling, Use, and
Storage of Flammable Compressed Gases (G-98)
- Hold and maintain Certificate of Fitness for Storage, Handling
and Use of Hazardous Materials (C-91)
- Hold and maintain Certificate of Qualification for
Refrigeration Operating Engineer (Q-01/Q-99/Z-51)
- Responsible for obtaining and maintaining other applicable NYC
Certificates of Fitness as required by the FDNY and/or other
authorities having jurisdiction.
- Hold and maintain PBS (Petroleum Bulk Storage) Class B
Operator
- Hold and maintain EPA 608 Universal Technician
Certification
- Hold and maintain a NATE Senior Specialty certification, and
the Commercial Refrigeration Service certification or equivalent
certification accepted by CUMVC Management
- NICET Certification in Inspection and Testing of Water-Based
Systems - Level III
- Responsible for obtaining and maintaining other applicable
Certifications as determined by management as the facility
develops. This may include additional NICET Certifications, PBS
Certifications, etc.
- Must be capable of performing fire brigade duties as
assigned.
- Hold and maintain OSHA 10 Certification
- Knowledge of and/or Training on the following:
- General OSHA standards and requirements.
- Use of portable fire extinguisher.
- Hazardous waste awareness.
- Asbestos hazards and safety.
- Computerized Maintenance Management Systems (work order
management system)
- Confined space entry procedures.
- Lock-out/Tag-out procedures.
- Description and use of fire stopping materials.
- Communication etiquette including phone, radio, and customer
service.
- Hot work permits.
- Must demonstrate knowledge of all CUMVC's safety policies and
procedures.
- Must demonstrate applicable institutional knowledge and
practices of the facility and its operations.
- Duties and requirements from Refrigeration Control Engineer
Level 2 and prior still apply and must be maintained and current,
as well as the knowledge applied to any future buildings coming on
line.
Physical Requirement & Environmental Conditions
The physical and environmental demands described here are
representative of those that must be met by an employee to
successfully perform the essential responsibilities and functions
of the job and are not meant to be all-inclusive.
- Use strength to lift and transport items needed to perform the
functions of the job, with the ability to lift 50 pounds
independently and support team lift with reasonable
accommodations.
- Sit, stand, bend, kneel, crouch, and squat for prolonged
periods of time and/or repeatedly over a required period of
time.
- Reach with and work with hands and arms overhead.
- May work in an environment where a variety of pathogens,
chemical substances, and gases are used for research.
- Ability to work while wearing a full-face respirator.
- Required to be Tuberculosis (TB) negative, submit to periodic
TB testing, and a chest x-ray if a positive TB test is
read.
- Able to perform work in power plant and campus
environments.
Employee will be required to practice the use of proper PPE when
exposed to the conditions above including participating in
pulmonary testing for the ability to wear respirators.
Preferred Qualifications
- Hold and maintain an active Motor Vehicle Class D License.
Equal Opportunity Employer / Disability / Veteran
Columbia University is committed to the hiring of qualified local
residents.
Keywords: Columbia University, Philadelphia , Refrigeration Control Engineer - Level 3, Engineering , New York, Pennsylvania
Didn't find what you're looking for? Search again!
Loading more jobs...